Start with the decision, not the activity
Activity dates are only the surface of a fit-out programme. The real logic sits in information release, long-lead procurement, area access, inspection gates, and commissioning dependencies.
A healthy review asks whether the next milestone has all of its entry conditions, not whether the previous bar appears green.
- Track information and procurement beside construction.
- Review milestones by entry and exit evidence.
- Measure area readiness, not broad percentage complete.

Turn intent into evidence
This makes progress conversations factual and brings delayed decisions into view before they consume float.
A sequence the team can use
- Find the constraints — Read decisions and material releases before reading installation dates.
- Test milestone evidence — Ask what must be approved, delivered, inspected, or energized.
- Follow the opening sequence — Work backwards from commissioning, training, and operational access.
Green bars can still hide red decisions
A programme update should expose pending information and approvals with the same discipline used for physical activities.